designing
and developing
security systems for You |
||||
|Home||
|
||||||||||||||||||||||||||||||||||
Roger Access control / Roger card+pin readers/Time & Attendance system |
||||||||||||||||||||||||||||||||||
![]() Battery is an optional accessory, not supplied in standard. |
||||||||||||||||||||||||||||||||||
Roger PR402
Single Door Access Controller |
||||||||||||||||||||||||||||||||||
MAIN
FEATURES:
Users Identification
Devices support and integration |
||||||||||||||||||||||||||||||||||
Software, Firmware
Hardware, Inputs/Outputs
|
||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||
Technical
specification |
||||||||||||||||||||||||||||||||||
| Power supply | 220-240VAC (transformer 30VA/18-22VAC secondary) | |||||||||||||||||||||||||||||||||
| Current consumption | ~ 30W | |||||||||||||||||||||||||||||||||
| Supply Output (nominal) | 13.8 VDC | |||||||||||||||||||||||||||||||||
| Tamper | Normally closed contact, 30V/50mA rated | |||||||||||||||||||||||||||||||||
| Communication standard RS485 | 'Christmas tree' bus topology allowed, terminating resistors not required. | |||||||||||||||||||||||||||||||||
| Cable distance between controller and terminal | 150 m (500 feet) | |||||||||||||||||||||||||||||||||
| Cable distance between controller and PC/ CPR panel | 1,200 m (4000 feet) | |||||||||||||||||||||||||||||||||
| Input lines | Four inputs, NO/NC type | |||||||||||||||||||||||||||||||||
| Output lines | Two transistor outputs 1A rating and two relay 1.5A/24V NO/NC contacts outputs | |||||||||||||||||||||||||||||||||
| Battery Charging Current | ~300 mA | |||||||||||||||||||||||||||||||||
| Battery Cut Off Level | ~10.0 V | |||||||||||||||||||||||||||||||||
| DC output | 12V/1A electronically protected | |||||||||||||||||||||||||||||||||
| Relative humidity | 10 to 95 % | |||||||||||||||||||||||||||||||||
| Operating temperature | 0 to 55 degrees centigrade | |||||||||||||||||||||||||||||||||
| Ingress code | IP30 (for internal use only, without water protection) | |||||||||||||||||||||||||||||||||
| Dimensions | 105X105X31 mm | |||||||||||||||||||||||||||||||||
| Weight | 175 g | |||||||||||||||||||||||||||||||||
| Roger
PRT32
* Standalone controller operation requires remote XM-2 I/O module |
![]() |
|||||||||||||||||||||||||||||||||
MAIN FEATURES RFID/PIN slave reader or simple standalone access controller, FEATURES WHEN CONFIGURED FOR STANDALONE CONTROLLER MODE: 120 cards and PINs, |
||||||||||||||||||||||||||||||||||
| Specifications Operating voltage range - 10...16VDC Current consumption - Avg. 60mA Tamper - Normally closed contact, 50mA/24V rated Reading range - Up to 12cm for ISO type cards (depends of card quality) Cards UNIQUE type, - EM4001/2 compatible. Communication interface - Wiegand26/34/42/64bit, Magstripe or RACS (Roger) Cable distance between host controller and slave reader - 150 meters (500 ft) Cable distance between reader and XM-2 or remote PRT reader (standalone controller option) - 150 m (500 ft) Input lines - One input built-in reader and two inputs on remote XM-2 I/O modules Output lines - Two relay NO/NC outputs 30V/1.5A rated on remote XM-2 I/O modules Relative humidity - 10...95% (non condensing) Operating temp. range - 0...+55º C Ingress protection code: - IP30 (for internal use only, without water protection) Dimensions - 105 X 105 X 31 mm Weight - 140g |
||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||
| Software
package to supervise Access Control system
|
||||||||||||||||||||||||||||||||||
Time & Attendance Evaluating data for time and attendance purpose does not require installation of any additional devices (readers or controllers) or using other kinds of identification cards in the system. To prepare the RACS system for T&A, it is necessary to mark controllers/terminals which will register employees' entrances or exits. Controllers can do both, access control and register events for T&A or can be assigned for one of mentioned function only. The RACS system offers several predefined types of passages (entrance, exit, business exit) and enables defining up to 150 additional types of passages as needed for the facility. For T&A purposes, we recommend using the PR302LCD controller, which enables dynamic modification of the type of the registered passage (with a keypad) or by the external push button or switch. In particular, it is needed where one controller registers multiple types of passages. The system RACS alone does not perform the T&A function, nevertheless, it may deliver input data for specialized T&A (Time & Attendance or PAYROLL) software modules. The wide capabilities of defining the format of text files, to which the program may export events, allow the system to be supported by numerous T&A packages available in the market. |
||||||||||||||||||||||||||||||||||
PR
Master 4.0 is a program to supervise access control system based on control
panels CPR-32 and CPR controllers delivered by Roger Company. Main features of PR Master 4.0: |
||||||||||||||||||||||||||||||||||
| Click here for pdf version of the catalogue | ||||||||||||||||||||||||||||||||||
For
information and sales please contact: Kenny
97523165 or email sales@securerus.com |
||||||||||||||||||||||||||||||||||
| secureRus
reg
no: 53041089M Tel no: 65 63451282 / Fax no: 65 62343769 111, North Bridge Road, #07-03, Peninsula Plaza, S179098 |
||||||||||||||||||||||||||||||||||